0
0
Watch list
was added to the project list.
×

About light and illumination

About light and illumination

Façade lighting

The look of a façade is the calling card of sophisticated architecture – the perfect luminaires are essential for staging cleverly designed exteriors at night.

Floor-level asymmetrical light for balanced façade illumination – four solutions




  • Slider
  • Slider
  • Slider
  • Slider
  • Wall clearance of the luminaire: 2 m. Excellent illumination up to a height of around 10 - 11 m


    84 164
    Drive-over in-ground luminaires
    4800 lm · 54.0 W



     
    Light

    • Soft light distribution
    • Illumination with great upward reach

    Perception of the luminaire

    • High-visibility, glare-free, linear light emission with a length of 1.50 m; optionally suitable as a continuous light band

    Control system

    • DALI controllable for illumination adjustment to suit the architectural conditions

    Installation

    • In-ground luminaires · pressure load 1000 kg
    • The luminaires are installed inside a recessed housing on a foundation that absorbs the pressure load
    • Installation interval between luminaires around 6 - 8 m
  • Wall clearance of the luminaire: 2 m. Excellent illumination up to a height of around 6 - 7 m


    84 155
    Drive-over in-ground luminaires
    2929 lm · 30.0 W



     
    Light

    • Soft light distribution
    • Slight, uniform upward luminance reduction

    Perception of the luminaire

    • Perceived as a glare-free light point in the ground

    Control system

    • DALI controllable for illumination adjustment to suit the architectural conditions

    Installation

    • In-ground luminaires · pressure load 2000 kg
    • The luminaires can be installed in an installation housing or as a "floating" solution
      (e.g. in gravel, green areas, flower beds, paved areas).
    • Installation interval between luminaires around 5 - 6 m
  • Wall clearance of the luminaire: 2 m. Excellent illumination up to a height of around 7 - 8 m


    84 618
    Drive-over in-ground luminaires
    2100 lm · 27.5 W



     
    Light

    • Wide and soft light distribution
    • Increased luminance in the lower part of the façade

    Perception of the luminaire

    • The light emission is directed solely at the surface to be illuminated and its individual light points are barely detectable with the human eye

    Control system

    • DALI controllable for illumination adjustment to suit the architectural conditions

    Installation

    • In-ground luminaires · pressure load 1000 kg
    • The luminaires are installed inside a recessed housing on a foundation that absorbs the pressure load.
    • Installation interval between luminaires around 8 - 9 m
  • Wall clearance of the luminaire: 2 m. Excellent illumination up to a height of around 9 - 10 m


    84 174
    LED on-ground luminaires
    4300 lm · 34.0 W



     
    Light

    • Very wide and uniform light distribution
    • Illumination with excellent upward reach

    Perception of the luminaire

    • The light emission is directed solely at the surface to be illuminated and its individual light points are barely detectable with the human eye

    Control system

    • DALI controllable for illumination adjustment to suit the architectural conditions

    Installation

    • On-ground luminaires
    • The luminaires are installed on a foundation, an anchorage unit or a connection housing via a mounting plate.
    • Installation interval between luminaires around 8 - 10 m