was added to the project list.
×

Drive-over LED in-ground luminaires

For installation situations with high pressure load and for flush-mounting installation · Location luminaires or floodlights


Location luminaires and adjustable floodlights specially for flush-mounting installation in paved ground surfaces. Luminaires with convincing lighting technology and impressive material quality. The patented luminaire construction made of stainless steel and cast stainless steel is characterised by a particularly high pressure load capacity of 5000 kg, making it suitable for very demanding applications – BEGA Patent EP 2 418 419.

Before the luminaires are installed, a foundation including drainage must be laid by the customer to absorb the pressure loads of the luminaires. The luminaires can be driven over by vehicles with pneumatic tyres.

Share

Pressure load 5000 kg
Material Stainless steel · Cast stainless steel
Protection class IP 68 10 m
Installation depth 130 - 255 mm
Size Ø 210 · 255 · 330 mm

BEGA Thermal Management ®

Trim ring and luminaire housing made of stainless steel and cast stainless steel
Safety glass
Floodlight reflector surface made of pure aluminium
Water stop · Connecting cable

20-year availability guarantee for LED modules

When the glass is wet, there may be a risk of slipping. For walkable public areas, we recommend skid-blocking glass in accordance with DIN 51130 R 13. With the additional specification R after the article number, we can supply all luminaires with skid-blocking glass. This increases the dispersion of the light distribution.

On request, the luminaires are available in the light colours green, blue, amber and red.

The luminaire luminous flux and the luminaire connected wattage quoted in the table may change as a result of technical progress. On our website you will find data sheets with information on each luminaire concerning not only the current values but also the LED service life and the luminous flux in relation to the respective colour temperature.

Planning examples

On the basis of our empirical values and the suggestions of architects and planners, we have compiled room situations for which lighting design is frequently required. In the following, we shall present possible illumination solutions for these architectural situations. It goes without saying that all technical lighting standards are complied with. In some cases, the degree of illuminance proposed by us may even exceed the standard. For us, the aesthetics of light and a high level of visual comfort are important criteria for such decisions. At the same time, the form and the size of the luminaires must fit into the architectural surroundings. For example, we often recommend larger models if a structure has large dimensions – even if smaller luminaires with lower output would be enough. In such cases, the degree of illuminance can be reduced to a suitable level by means of a light control system.


Historical façade

Various different luminaires are used to illuminate historical façades. Beginning on the ground floor, arcades are illuminated with in-ground floodlights. Here it is important to make sure that the luminaires can stand up to being driven over by car tyres. Depending on the version of the luminaires, pressure loads of up to 5000 kg are possible. Between the floors, the house has ledges from where...

learn more


LED colour temperature
Glass surface
Location luminaires 
  LED Power supply unit β A B AC/DC
77 071 K3   5.7 W 77 lm on/off 210 130
77 072 K3   10.0 W 165 lm DALI controllable 255 130
77 073 K3   9.0 W 600 lm DALI controllable 330 155
 
Floodlights · Adjustable inclination angle 0° to 30°/ vertical axis ±180° 
  LED Power supply unit β A B AC/DC
77 074 K3   11.0 W 601 lm DALI controllable 10° 210 200
77 629 K3   13.8 W 952 lm DALI controllable 16° 255 225
77 852 K3   20.5 W 1226 lm DALI controllable 15° 330 255
no longer included in the current catalogue new in the range