Symmetrical or asymmetrical flat beam light distribution · With 1 or 2 adjustable floodlights


Light building elements are luminous design elements for public areas. They are particularly suitable for dividing and structuring outdoor spaces. They can be used to guide or lead people and vehicles. Their attention-drawing power is considerably greater than that of pole-top luminaires. Light building elements can be used to serve or highlight the architectural structure. These light building elements are ideal for the energy-efficient illumination of streets, parking spaces and traffic-calmed areas.

They are available with a choice of symmetrical or asymmetrical flat beam light distribution and with different mounting heights. Symmetrical light distribution is ideal for illuminating squares, while asymmetrical flat beam light distribution is particularly suitable for illuminating streets.

more
Share

Protection class IP 65
BEGA Thermal Management ®

Cast aluminium, aluminium and stainless steel
Synthetic cylinder, clear
Reflector made of pure anodised aluminium

BEGA Ultimate Driver ®
DALI controllable

20-year availability guarantee for LED modules

Luminaires without additional floodlights: Door and connection box 71084
Luminaires with additional floodlights: Door and connection box 70647

The inclination angle of the individual floodlights is adjustable from 0° to 30°.
The individual floodlights can be rotated by 360° around the vertical axis of the light building element.
We can also supply these luminaires with a base plate and in safety class II as custom-made products.

The luminaire luminous flux and the luminaire connected wattage quoted in the table may change as a result of technical progress. On our website you will find data sheets with information on each luminaire concerning not only the current values but also the LED service life and the luminous flux in relation to the respective colour temperature.

Planning examples

On the basis of our empirical values and the suggestions of architects and planners, we have compiled room situations for which lighting design is frequently required. In the following, we shall present possible illumination solutions for these architectural situations. It goes without saying that all technical lighting standards are complied with. In some cases, the degree of illuminance proposed by us may even exceed the standard. For us, the aesthetics of light and a high level of visual comfort are important criteria for such decisions. At the same time, the form and the size of the luminaires must fit into the architectural surroundings. For example, we often recommend larger models if a structure has large dimensions – even if smaller luminaires with lower output would be enough. In such cases, the degree of illuminance can be reduced to a suitable level by means of a light control system.


Train station forecourt

A forecourt of 40 x 20 m opens up in front of a station. This area is bordered by a low wall, which is interrupted by a staircase. This staircase is used to reach street level. Recessed wall luminaires are installed in the wall and in the steps of the staircase for orientation and guidance purposes. The forecourt is illuminated and at the same time structured by light building elements. These are...

learn more


Finish
LED colour temperature
Symmetrical light distribution 
  LED Power supply unit β A B C D AC/DC
84 137 K3   22.5 W 2375 lm DALI controllable 140 450 4000 800
88 064 K3   33.0 W 3663 lm DALI controllable 170 600 4500 800
88 065 K3   52.0 W 6279 lm DALI controllable 220 700 5000 1000
 
Symmetrical light distribution · 1 floodlight 
  LED Power supply unit β A B C D AC/DC
88 863 K3   32.9 W 3663 lm DALI controllable 170 600 4500 800
  1x 7.0 W 610 lm 17°
88 063 K3   57.7 W 6279 lm DALI controllable 220 700 5000 1000
  1x 13.0 W 1115 lm 14°
 
Symmetrical light distribution · 2 floodlights 
  LED Power supply unit β A B C D AC/DC
88 865 K3   33.0 W 3663 lm DALI controllable 170 600 4500 800
  2x 7.0 W 610 lm 17°
88 070 K3   57.7 W 6279 lm DALI controllable 220 700 5000 1000
  2x 13.0 W 1115 lm 14°
 
Asymmetrical flat beam light distribution 
  LED Power supply unit β A B C D AC/DC
84 138 K3   22.5 W 2294 lm DALI controllable 140 450 4000 800
88 067 K3   33.0 W 3636 lm DALI controllable 170 600 4500 800
88 068 K3   52.0 W 6217 lm DALI controllable 220 700 5000 1000
 
Asymmetrical flat beam light distribution · 1 floodlight 
  LED Power supply unit β A B C D AC/DC
84 261 K3   33.0 W 3636 lm DALI controllable 170 600 4500 800
  1x 7.0 W 610 lm 17°
84 263 K3   52.0 W 6217 lm DALI controllable 220 700 5000 1000
  1x 13.0 W 1115 lm 14°
 
Asymmetrical flat beam light distribution · 2 floodlights 
  LED Power supply unit β A B C D AC/DC
84 262 K3   33.0 W 3636 lm DALI controllable 170 600 4500 800
  2x 7.0 W 610 lm 17°
84 264 K3   52.0 W 6217 lm DALI controllable 220 700 5000 1000
  2x 13.0 W 1115 lm 14°

LED light building elements in use