LED wall washers

Light emission on one side · Symmetrical, asymmetrical or flat beam light distribution


A group of LED wall washers with three light distributions for different lighting requirements:
• symmetrical light distribution to illuminate façade and wall surfaces, with the mounting surface also acting as a reflection surface.
• asymmetrical light distribution for illuminating the ground surfaces in front of walls and facades. Here, the main focus is on the spatial illumination of the ground surfaces.
• Flat beam light distribution for illuminating the ground surfaces in front of walls and facades. Here, the main focus is on the flat beam illumination of the surfaces near the building.

These are cost-effective dimmable luminaires with high luminous efficiency, low connected wattage and long LED service life.

The luminaires can be installed in any burning position. In this way, surfaces adjacent to the installation surface can be illuminated, for example ceilings, arches, canopies and cantilever plates.

more
Share

Protection class IP 65

Cast aluminium, aluminium and stainless steel
Safety glass
Reflector made of pure anodised aluminium

DALI controllable

The luminaires can be installed in any burning position.

The luminaire luminous flux and the luminaire connected wattage quoted in the table might change as a result of technical progress. On our website you will find data sheets with information on each luminaire concerning not only the current values but also the LED service life and the luminous flux in relation to the respective colour temperature.

Planning examples

On the basis of our empirical values and the suggestions of architects and planners, we have compiled room situations for which lighting design is frequently required. In the following, we shall present possible illumination solutions for these architectural situations. It goes without saying that all technical lighting standards are complied with. In some cases, the degree of illuminance proposed by us may even exceed the standard. For us, the aesthetics of light and a high level of visual comfort are important criteria for such decisions. At the same time, the form and the size of the luminaires must fit into the architectural surroundings. For example, we often recommend larger models if a structure has large dimensions – even if smaller luminaires with lower output would be enough. In such cases, the degree of illuminance can be reduced to a suitable level by means of a light control system.


Loading zone

Good light in a loading and manoeuvring zone guarantees safety and smooth working processes. Where there are several adjacent loading openings in a building, glare-free luminaires are therefore placed above and between the gates. Their asymmetrical very wide beam light distribution creates a degree of illuminance of about 50 lx. In addition, location luminaires are installed in the wall about...

learn more


Finish
LED colour temperature
Symmetrical light distribution 
  LED Power supply unit A B C AC/DC
22 392 K3   21.5 W 2908 lm DALI controllable 240 105 200
33 388 K3   33.5 W 4662 lm DALI controllable 320 125 220
 
Asymmetrical light distribution 
  LED Power supply unit A B C AC/DC
22 386 K3   21.5 W 2011 lm DALI controllable 240 105 200
33 386 K3   34.0 W 4416 lm DALI controllable 320 125 220
 
flat beam light distribution 
  LED Power supply unit A B C AC/DC
22 383 K3   19.0 W 2324 lm DALI controllable 240 105 200
33 378 K3   31.6 W 3676 lm DALI controllable 320 125 220

LED wall washers in use