Recessed ceiling luminaires · Downlights

Symmetrical narrow beam, symmetrical wide beam, symmetrical very wide beam or asymmetrical wide beam light distribution


Square downlights with patented Vortex Optics ® with various LED outputs, half beam angles and dimensions for installation in suspended ceilings – as well as in concrete ceilings by means of installation housings.

These luminaires are available with symmetrical narrow beam, symmetrical wide beam, symmetrical very wide beam or asymmetrical light distribution and in different lengths for various lighting applications.
Our patented reflectors (European Patent EP 3098504) enable perfect light deflection through intensive concentration of the light with maximum visual comfort.

The external power supply units are included in the scope of delivery and are connected to the luminaire by means of a convenient plug connector. The electrical connection of the power supply unit can therefore be established before the final installation of the luminaire, if required by the customer.

more

Protection class IP 65
BEGA Thermal Management ®

Cast aluminium, aluminium and stainless steel
BEGA Unidure ® coating technology
Safety glass
Reflector surface made of pure aluminium
BEGA Vortex Optics ®

External power supply units included on/off or DALI

20-year availability guarantee for LED modules

The required installation depths can be found in the instructions for use for these luminaires.

Suitable installation housings for installing the luminaire and power supply unit in concrete ceilings can be found in the table.

The luminaire luminous flux and the luminaire connected wattage quoted in the table may change as a result of technical progress. On our website you will find data sheets with information on each luminaire concerning not only the current values but also the LED service life and the luminous flux in relation to the respective colour temperature.

Planning examples

On the basis of our empirical values and the suggestions of architects and planners, we have compiled room situations for which lighting design is frequently required. In the following, we shall present possible illumination solutions for these architectural situations. It goes without saying that all technical lighting standards are complied with. In some cases, the degree of illuminance proposed by us may even exceed the standard. For us, the aesthetics of light and a high level of visual comfort are important criteria for such decisions. At the same time, the form and the size of the luminaires must fit into the architectural surroundings. For example, we often recommend larger models if a structure has large dimensions – even if smaller luminaires with lower output would be enough. In such cases, the degree of illuminance can be reduced to a suitable level by means of a light control system.


Underground car park

Here too, the focus is on the safety of the road users. The transition into the underground car park must be illuminated in accordance with the time of day in order to prevent extreme changes between light and dark. This means that this area must be illuminated with 300 lx during the day and 75 lx at night. The illumination can be adjusted using twilight switches and the BEGA Control light...

learn more


Commercial building entrance

The covered area in front of a commercial building is illuminated from a great height with efficient downlights. The focus is placed on the square pillars supporting the roof using very narrow beam in-ground floodlights on the front side. On the sides and at the rear, they benefit from the light of the downlights. A roof panel projecting over the entrance is fitted with recessed ceiling luminaires...

learn more


Office building entrance

A company is represented by the entrance area to its company building. Here, glare-free light should be used to clearly illuminate the way to the entrance door and at the same time to ensure good face recognition in the door area. On-ground luminaires are used to illuminate the path to the building; their light reaches far into the surface of the path, but without glare. Unshielded wall luminaires...

learn more


Shopping mall

The general illumination of the shopping mall is effected by downlights from a height of 12 m. The light is uniform and glare-free. The main area of the mall measures 28 x 65 m. The surrounding galleries are illuminated by recessed ceiling luminaires. Additional light falls into the room from the adjacent shop windows. Individually adjustable compact floodlights on the borders of the galleries...

learn more


Spa

In a spa zone, the illumination makes a significant contribution towards the well-being of the guests. Alternating zones with dimmed light and zones accentuated with illumination are ideal for the relaxation of the guests. At the same time, the lighting system must be able to illuminate the rooms clearly for cleaning purposes. On account of the climatic conditions in such facilities, only luminaires...

learn more


Finish
LED colour temperature
Symmetrical narrow beam light distribution 
LED Power supply unit β A B AC/DC
 
 
Symmetrical wide beam light distribution 
LED Power supply unit β A B AC/DC
 
 
Symmetrical very wide beam light distribution 
LED Power supply unit β A B AC/DC
 
 
Asymmetrical light distribution 
LED Power supply unit β A B AC/DC
 
no longer included in the current catalogue new in the range

Recessed ceiling luminaires · Downlights in use

Slider
Thermo Sensor Headquarters, Werne Learn more
Slider
Clouth Quarter, Cologne Learn more
Slider
Westfalenbad Hagen, Germany Learn more
Slider
Villa in Unna, Germany Learn more